Service Guide. Publication Number (order as manual set) The security code is set to “HP” when the function generator is. Note: Unless otherwise indicated, this manual applies to all Serial Numbers. The Agilent .. For information on using the Phase-Lock Option for the HP A. Microsoft® Windows® included. Agilent A. 15 MHz Function /. Arbitrary Waveform Generator. Note: Unless otherwise indicated, this manual applies to all .

Author: Akibei Najinn
Country: Martinique
Language: English (Spanish)
Genre: Life
Published (Last): 13 September 2015
Pages: 312
PDF File Size: 4.97 Mb
ePub File Size: 18.65 Mb
ISBN: 158-5-92109-394-2
Downloads: 28905
Price: Free* [*Free Regsitration Required]
Uploader: Sarn

Chapter 3 Features and Functions Burst Modulation Burst Modulation You can configure the function generator to output a waveform with a specified number of cycles, called a burst.

For certain applications where you may not want to output the sync signal, you manuaal disable the SYNC terminal. Page 50 Chapter 3 Features and Functions Output Configuration Output Amplitude As shown below, the output amplitude range depends on the function currently selected and the output termination. You can output these waveforms directly from non-volatile memory.

Page 6 Quick Start The following steps show you how to change the frequency to 1. This enables you to recall the entire instrument configuration with a single command from the remote interface or with just a few key presses from the front panel.

HP 33120A User Manual

If you continued change to a function that is not allowed with the selected modulation, the modulation mode is turned off. Chapter 2 Front-Panel Menu Operation A front-panel menu amnual Menu Example 3 Some commands in the menu require that you enter a numeric parameter value.

Chapter 2 Front-Panel Menu Operation To trigger a burst or sweep To trigger a burst or sweep You can issue triggers from the front-panel for burst modulation and frequency sweeps using single trigger or internal trigger.

Page 28 Chapter 2 Front-Panel Menu Operation A front-panel menu tutorial Menu Example 2 The following example shows how to use the recall menu feature as a shortcut to set the command back to its original setting. To print the manual completely, please, download it.

HP A USER MANUAL Pdf Download.

Page 73 Chapter 3 Features and Functions Burst Modulation Burst Trigger Source In the triggered burst mode, the function generator outputs a waveform with the specified number of cycles burst count each time a trigger is received.

  FORMS SA100 PDF

Chapter 2 Front-Panel Menu Operation To output a burst waveform To output a burst waveform You can configure the function generator to output a waveform with a specified number of cycles, called a burst.

Page Chapter 3 Features and Functions System-Related Operations Display Control To speed up the rate at which the function generator can make configuration changes, or for security reasons, you may want to turn off the front-panel display.

The following steps show you how to change the offset to —1. Chapter 1 Quick Start To output a stored arbitrary waveform To output a stored arbitrary waveform There are five built-in arbitrary waveforms stored in non-volatile memory for your use. For example, if you output a 1 MHz sine wave and then change the function to triangle wave, the function generator will adjust the output to kHz the upper limit for triangle waves.

Page 94 Chapter 3 Features and Functions Arbitrary Waveforms Arbitrary Waveforms There are five built-in arbitrary waveforms stored in non-volatile memory. The bus address is displayed. Page 86 Chapter 3 Features and Functions Frequency Sweep Start Frequency and Stop Frequency The start frequency and stop frequency set hp33120a upper and lower frequency bounds for the sweep. The five built-in arbitrary waveforms can be output at a maximum of 5 MHz. At this point, the pulse waveform is being output from volatile memory.

This enables you to recall the entire instrument configuration with just a few key presses from the front panel. Chapter 2 Front-Panel Menu Operation A front-panel menu tutorial A front-panel menu tutorial This section is a step-by-step tutorial which shows you how to use the front-panel menu.

Unless otherwise indicated, this manual applies to all Serial Numbers. The function generator calculates the average of the data points and compares the average to zero volts. The default is Sine. After the specified number of cycles has been output, the function generator waits for the next trigger while outputting no signal zero volts or the dc offset level. Page 42 Chapter 2 Front-Panel Manuaal Operation To trigger a burst or sweep To trigger a burst or sweep You can issue triggers from the front-panel for burst modulation and frequency sweeps using single trigger or internal trigger.

  EN QUE PIENSAS XAVIER VILLAURRUTIA PDF

In amplitude modulationthe amplitude of the carrier is varied by the amplitude of the modulating waveform. Chapter 2 Front-Panel Menu Operation To output a modulated waveform To output a modulated waveform A modulated waveform consists of a carrier and a modulating np33120a.

Page Chapter 3 Features and Functions Calibration Overview To Change the Security Code To change the security code, you manuual first unsecure the function generator, and then enter a new code. Got it, continue to print. Ampl 1 Enable the amplitude modify mode.

Chapter 3 Features and Functions Frequency Sweep Sweep Trigger Source In the triggered sweep mode, the function generator outputs a single sweep each time a trigger is received. You can output the burst at a rate determined by the internal rate generator or an external signal applied to the rear-panel connector.

Chapter 2 Front-Panel Menu Operation A front-panel menu tutorial Menu Example 2 The following example shows how to use the recall menu feature as a shortcut to set the command back to its original setting.

The rate is set to baud when the function generator is shipped from the factory. You are then exited from the menu. The following steps show you how to change the amplitude to 50 mVrms.

Duty cycle manusl specified as a percentage and represents the amount of time per cycle that the square wave is high.

The function generator outputs one burst or Single initiates one sweep each time you press the key. The HP A is a high-performance 15 MHz synthesized function generator with built-in arbitrary waveform capability.

Page 92 Group Execute Trigger message. Chapter 3 Features and Functions Output Configuration Output Frequency As shown below, the output frequency range depends on the function currently selected.